LPK2EB-KTC1,LPK2EB-KTC1,LPB2EB-KTC1,LPB2EB-KTC1,LPD3EB-KTC1.LPD3EB-KTC1,LPF4EB-KTC1,LPF4EB-KTC1,LPH4EB-KTC1,LPH4EB-KTC1,
LPD4EB-KTC1,LPD4EB-KTC1,LPG4EB-KTC1,LPG4EB-KTC1,LPK5EB-KTC3,LPK5EB-KTC3,LPH5EB-KTC3,LPH5EB-KTC3,LPA3EB-KTC1,LPA3EB-KTC1,
LPK3EB-KTC1,LPK3EB-KTC1,LPB4EB-KTC1,LPB4EB-KTC1,LPE4EB-KTC3,LPE4EB-KTC3,LPG5EB-KTC3,LPG5EB-KTC3,LPH6EB-KTC3,LPH6EB-KTC3,
LPK7EB-KTC3,LPK7EB-KTC3,LPH7EB-KTC3,LPH7EB-KTC3,LVH7EB-WTSK*,LPJ8EB-PTCB*,LPH8EB-PTCB*
?所有型號標配: 三功能閥,注射閥, 底閥, 進出口軟管(標*的型號無三功能閥) ?電源:220V*大功率:300W
?配五功能閥需單獨訂貨
?PVC泵頭可選,價格與PVDF泵頭材質相同.
美國帕斯菲達pulsafeeder電磁計量泵LPH4EB-KTC1,加藥泵流量調節(jié)方式:脈沖+液位信號控制,泵頭材質:PVDF
*手動:頻率,沖程同時可調 *流量0.5-95升/小時,壓力2-21Bar *自動:可選4-20mA脈沖信號,液位信號接收功能 *21種機型
美國帕斯菲達pulsafeeder電磁計量泵LPH4EB-KTC1,加藥泵流量調節(jié)方式:脈沖+液位信號控制,泵頭材質:PVDF
? 如果排放管路中的流體壓力低于環(huán)境壓丿J.則在排放管路屮使用抗虹吸閥。如果注入點位于水
泵吸入端,或者靠著“負”壓頭,如在往下給送到井中時,則會發(fā)生虹吸作用。
管道
連接時使用提供的規(guī)定尺寸的管道。管道連接要牢固,防止化學藥品泄漏和空 氣進入。由于配件中使用塑料螺母,因此不可過度擰緊配件,即只能用手擰緊。 NPT(美國標準錐管螺紋)吸入閥和排放閥決不可擰得過緊。NPT 吸入閥和排 放閥只能擰緊到 25-35 英寸磅(4.5-6.3 kg/cm)。? 如果使用放氣閥組件,則應可靠地連接一條回流管路(軟管),回流管路連接回 到儲罐。要避免化學藥品可能造成的傷害,沒有安裝回流管路前決不要嘗試使 用放氣閥啟動。
如果泵是架式安裝,或安裝在儲罐頂上,進口軟管應盡可能短。
? 提供一臺背壓/注入閥以保持計量性能。標準注入閥中的彈簧典型地增加 17-20 PSI(1.17 – 1.38 BAR)到管路壓力上,H8 泵除外,這種泵增加 8-10 PSI(.55-.69 BAR)。注入閥必須安裝在排放管路中。*好的方法是將注入閥安裝在化學藥 品注入點。
? 如果排放管會暴露于直射陽光,應使用黑色管來代替隨泵提供的標準白色半透 明管。如需要黑色管,請與供應商聯系。要防止堵塞或避免止回閥發(fā)生故障,請務必在吸入管末端安裝一套過濾器組件這套底閥/過濾器組件務必安裝在距離儲罐底部上方 1-2 英寸(2-5 cm) 處,這樣可以避免儲罐底部可能積聚的固體堵塞過濾器?;瘜W藥品儲罐和底閥/ 過濾器應定期清洗,確保連續(xù)**運行。如果溶液中周期性地沉淀出正在泵送 的化學藥品,或者化學藥品難以溶解或不能完全溶解(如氫氧化鈣),則應在化 學藥品儲罐中使用混合器。這些在許多電動機配置和安裝中都很容易提供。如 需要可與供應商聯系。
? 如果注入點的稀釋不是很快進行,則 會導致管道腐蝕。這個問題很容易避 免,只要遵守下面這一簡單規(guī)則:安 裝注入接頭,使其端部伸入涉及管路 的液流中央。根據需要修整注入器頂端。
注:可提供適用于大型水管線路的延長注入組件。如欲了解更 多信息,請與供應商聯系。
本泵配備的電源插頭為三腳接地型。要減少電擊危險,只可連接到已正確接地的接地型插座。
計量泵連接的電源必須與泵的數據標簽上的電源一致。如果施加的電壓高 于泵的額定值,則會損壞內部電路。
在控制裝置的電子電路中,通過過電壓吸收元件和高壓半導體來測量沖擊 電壓。盡管如此,過量的沖擊電壓可能在某些區(qū)域中導致故障。因此,不 可與產生高壓的重型電氣設備共用一個插座。但是,如果必須共用一個插 座,則應采取措施,(a)在泵的電源連接上安裝過電壓吸收元件(可變電 阻,波沖電阻*小 2000A),或(b)安裝噪聲抑制變壓器。
PULSAtron Series E Plus Metering Pump
504 GPD @ 20 PSI, 230 VAC4-20 mA Input with Dual Manual Control and Stop Function Input
Stroke frequency control via 4-20 mA signal input, manual stroke length control. Stroke frequency is manually adjustable when in local control. Includes stop function input.
General Description
Pulsafeeder PULSAtron Series E Plus chemical metering pumps are positive displacement, diaphragm type pumps. Output volume is adjustable while pumps are in operation from zero to maximum capacity. The PULSAtron Series E Plus contains a highly reliable timing circuit as well as circuit protection against voltage and current upsets. This pump features solenoid protection by thermal overload with auto-reset. The Series E Plus guided check valves, with their state-of-the-art seat and ball designs, provide precise seating, and excellent priming and suction lift characteristics. Our timing circuit is highly reliable and, by design, virtually unaffected by temperature, EMI and other electrical disturbances.
Pump Controls
Adjustment is by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency. Both knobs are located opposite the liquid handling end. Automatic control via 脈沖 DC and stop function inputs. Auto-Off-Manual switch.
Drive Assembly
The pump drive is totally enclosed with no exposed moving parts. Electronics are housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Average electrical power consumption is 130 Watts.
Materials of Construction
See Specifications tab. Chemical metering pump housing shall be of chemically resistant PBT thermoplastic. All exposed fasteners are stainless steel. Valve seat and seal ring are renewable by replacing the cartridge valve assembly.
Pulsafeeder PULSAtron Series E Plus Chemical Metering Pump - Key Features
- Manual Control by on-line adjustable stroke rate and stroke length.
- Highly Reliable timing circuit.
- Circuit Protection against voltage and current upsets.
- Panel Mounted Fuse.
- Solenoid Protection by thermal overload with auto-reset.
- Water Resistant, for outdoor and indoor applications.
- Indicator Lights, panel mounted.
- Guided Ball Check Valve Systems, to reduce back flow and enhance outstanding priming characteristics.
- Few Moving Parts and Wall Mountable.
- Safe & Easy Priming with durable leak-free bleed valve assembly (standard).
- Reliable metering performance.
- Rated "hot" for continuous duty.
- Leak-free, sealless, liquid end.
Includes:
A weighted foot valve/strainer assembly, a 1/2" NPT male injection fitting/back pressure check valve assembly, 4' suction tubing, 8' discharge tubing and Owners Manual